The 2-Minute Rule for ATS Socomec

Intuitive operation - The high-resolution Liquid crystal display monitor presents quite a few dashboards enabling quick checking of all parameters, which include electric power and Electricity intake on the loads.

Good Grid, storage for integrating renewable Electricity and islanding Paradise, a smart network for that local people Solenbat optimises the active Strength performance of buildings Stem, energy storage systems for reduced electrical energy billing Innovation Close

ATyS C66 assures automated and guide transfer from a single supply to another with totally configurable timers and thresholds and may be door-mounted or panel-mounted. In addition, our controller is compatible with our DIRIS Digiware solutions.

ATyS t and g switches present important time preserving throughout commissioning (course of action usually takes two to three minutes). Owing to the design that permits commissioning as a result of just two potentiometers (4 within the ATyS g) and four DIP switches, a scrrewdriver is all of that is needed to configure the parameters.

Versatile programming ATyS p M time delays and inputs/outputs are wholly configurable, consequently enabling the straightforward monitoring of particular purposes (load shedding, take a look at…) as well as the definition of an running cycle particularly tailored to the application.

รับสมัครช่างวายริ่งตู้คอนโทรล,ช่างไฟฟ้า,ช่างประกอบตู้คอนโทรล รับทำตู้ไฟชั่วคราว ตู้ไฟสนาม ตู้มิเตอร์

รับประกอบตู้ไฟฟ้า – ตู้ควบคุมทุกชนิด

They can be intended to be used in minimal voltage electric power provide systems where by a quick interruption of your load provide is appropriate for the duration of transfer.

Configuration software package Program (Easyconfig) is accessible enabling the ATyS p parameters being simply configured and the present configuration for being saved and sent to other models.

Handheld remote control interface Specially made for installations exactly where the products is enclosed, the distant interface displays product or service standing on the entrance panel (D10) or displays and controls with use of programming (D20).

The ATyS C66 is really an ATSE controller created to Command every type of crisis methods, legally demanded and optional standby transfer switching tools According to NEC (NFPA 70).

Stability and trustworthiness ATyS p ATS Socomec have both equally electrical and mechanical interlocks for optimum safety. The 0 placement gives electrical security disconnection and enables TSE lockout as per IEC60947-three.

Awesome Grid, storage for integrating renewable Electricity and islanding Paradise, a smart community to the local community Solenbat optimises the Energetic Vitality performance of structures Stem, energy storage devices for diminished electricity billing Innovation Near

- All main functions for example distant posture control, mode assortment, lamp take a look at and genset exam on load are available around the front on the product or service letting swift and simple Procedure.

Journey purpose ATyS p M encompasses a perform for returning on the 0 placement in the event of the lack of the two electric power provide sources (tripping). This guards the load from issues resulting from source instability.

Leave a Reply